Electrical Testing and Preventative Maintenance
C3 Engineering | Compliance
Preventative Maintenance
Whether you are talking about your family vehicle, a widget factory or an electrical substation a robust Electrical Preventive Maintenance (PM) program is the very foundation of reliability. Besides safety and reliability, some studies show that unplanned maintenance costs can be up to six or seven times the costs of planned maintenance, or issues corrected during PM. We can evaluate your equipment and create PM programs that meet manufacturers’ and industry specifications in regards to the types of tests, intervals and more. ANSI, NETA, NFPA, OSHA – we’ll take the mystery out of required and recommended Preventive Maintenance. Whether you are in need of a simple Infrared scan (IR) or a complex Shutdown, Turnaround & Outage (STO), we’ll be there to manage every step of the process to make sure ensure your equipment runs safely, efficiently and reliably.
We can also support you and your teams with the following Field Services.
Contact us today to learn more about how our services can help your company succeed!
General Field Services
- Electrical System Troubleshooting and Repair
- Preventative Maintenance of Electrical Apparatus
- Shutdowns, Turnarounds, & Outages (STO) – Project Management and Temporary power
- Insulation Resistance Testing (All Voltage Classes)
- High Potential Testing (HiPot)
- Low, Medium and High Voltage Cable Testing
- Very Low Frequency (VLF) and Tan-Delta Testing
- Ground Fault Systems
- Motors & Generators (Inrush, Vibration & Surge Comparison Testing)
- Uninterruptible Power Supplies (UPS)
- Batteries (UPS, Controls, etc.)
- Automatic Transfer Switches
- Testing, Repair and System Upgrades
- Capital Upgrades
- Variable Speed / Frequency Drives (VFDs)
- Infrared Thermography (IR Scanning)
- Kilowatt Hour Meter Calibration
- Instrumentation
- Fused Switches
- Upgrades / Replacements
Power Generation & Substations
- Station-Class Breaker Testing
- Protective Relay Calibration
- Paralleling Switchgear
- On-Line Partial Discharge Testing
- Power Generators
Transformers
- Insulation Power Factor Testing
- Transformer Turns Ratio Testing (TTR)
- Insulation Resistance Testing
- Sweep Frequency Response Analysis (SFRA)
- Oil Sample Analysis
- Auxiliary Device Testing
- Winding Resistance Testing
Grounding
- Ground Resistance Testing and Modeling
- Soil Resistivity Testing and Modeling
Circuit Breakers
- Low, Medium & High-Voltage Class
- Trip Units – Retro-Fit / Upgrades
- SF6 Breaker Timing & Power Factor Testing
Cabling
- Insulation Resistance
- On Line/Off Line Testing
- Very Low Frequency (VLF) Tan Delta